Table of Contents
-
Environmental Safety
-
Electrical Safety
-
Hazardous Location Installation Requirements
-
Package Contents
-
Installation
-
Front Panel
-
Applying Power
-
Rj45 Connector Crimp Specifications
-
Connecting the Unit
-
Troubleshooting
-
Fcc Statement
-
Industry Canada
Advertisem*nt
Quick Links
- 1 Installation
- Download this manual
100 Series
Media Converter &
Industrial Ethernet Switches
User Manual &
Installation
Guide
Table ofContents
Advertisem*nt
Table of Contents
Related Manuals for N-Tron 100 Series
-
Network Hardware N-Tron 100 Series User Manual
100 series media converter & industrial ethernet switches (19 pages)
-
Switch N-Tron 702-W Features
N-tron hub/switch product manual (2 pages)
-
100 series media converter & industrial ethernet switches (39 pages)
-
Industrial media converter (15 pages)
-
Network Router N-Tron 104TX Specification Sheet
Unmanaged four port industrial ethernet switch (2 pages)
-
Switch N-Tron 105TX-SL Instruction Sheet
(1 page)
-
Industrial power extractor (16 pages)
-
Unmanaged industrial 4-port mid-span poe pse (18 pages)
-
Unmanaged industrial 4-port mid-span poe pse (18 pages)
-
Switch N-Tron 105M12 Installation Manual
Industrial ethernet switches (16 pages)
-
Switch N-Tron 108M12 Installation Manual
Industrial ethernet switches (16 pages)
-
Unmanaged industrial ethernet poe switches (20 pages)
-
1000 series gigabit media converter & industrial gigabit ethernet switch (21 pages)
-
700 series managed industrial ethernet switch (154 pages)
-
Switch N-Tron 400 Series Installation Manual
400 series industrial ethernet switches (17 pages)
-
Switch N-Tron 508TX Installation Manual
500 seriesindustrial ethernet switches (71 pages)
Summary of Contents for N-Tron 100 Series
- Page 1 100 Series Media Converter & Industrial Ethernet Switches User Manual & Installation Guide...
- Page 2 Industrial Media Converter and Ethernet Switch Installation Guide 102MC-XX 105TX 106FX2 110FX2-XX-YY 102MCE-XX-YY 105TX-SL 108TX 111FX3-XX-YY 104TX 105FX-XX 108TX-HV 112FX4-XX-YY 105FXE-XX-YY 114FX6-XX-YY 116TX Where: XX=ST or SC and YY= 15, 40 or 80 (Revised 2015-09-28)
- Page 3 In no event shall N-TRON Corporation be liable for any incidental, special, indirect or consequential damages whatsoever included but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein.
-
Page 4: Environmental Safety
AVERTISsem*nT: Ne pas utiliser le matériel en présence de gaz ou de vapeurs inflammables. L'utilisation de matériel électrique dans un tel environnement constitue un danger certain. WARNING: If the equipment is used in the manner not specified by N-TRON Corporation, the protection provided by the equipment may be impaired. -
Page 5: Electrical Safety
ELECTRICAL SAFETY WARNING: Disconnect the power cable before removing the end plates. AVERTISsem*nT: Débranchez le câble d'alimentation avant de retirer les plaques d'extrémité. WARNING: Do not operate the unit with the end plates removed. AVERTISsem*nT: Ne pas faire fonctionner l'appareil avec les plaques d'extrémité supprimées. WARNING: Never install or work on electrical equipment or cabling during periods of lightning activity. -
Page 6: Hazardous Location Installation Requirements
HAZARDOUS LOCATION INSTALLATION REQUIREMENTS 1. This equipment is suitable for use in Class I, Div 2, Groups A, B, C, and D, or unclassified or non- hazardous locations only. Cet équipement est adapté seulement pour utilisation dans la classe I, Division 2, Groupes A, B, C, D ou seulement dans les endroits non-dangereux. - Page 7 Relais U13. 100 Series Industrial Ethernet Switches The 100 Series Unmanaged Industrial Ethernet Switches support high speed layer 2 switching between ports. This series of switches are housed in a ruggedized aluminum enclosure, and provide Category-5 compliant 10/100-BaseT connections for high performance network design, and hub/repeater upgrades.
-
Page 8: Package Contents
Up to 3.2 Gb/s Maximum Throughput Industry Standard 35mm DIN Rail Mounted Enclosure PACKAGE CONTENTS Please make sure the package contains the following items: 100 Series Media Converter or Ethernet Switch Instruction Sheet Contact your carrier if any items are damaged. UNPACKING Remove all the equipment from the packaging, and store the packaging in a safe place. - Page 9 WARNING AVERTISsem*nT WARNING: Never install or work on electrical equipment or cabling during periods of lightning activity. AVERTISsem*nT: Ne jamais installer ou de travailler sur un équipement électrique ou de câblage pendant les périodes d'activité de la foudre. WARNING: Do not operate the equipment in the presence of flammable gasses or fumes. Operating electrical equipment in such an environment constitutes a definite safety hazard.
- Page 10 To install the plastic clip units to 35mm To remove the plastic clip units from the industrial DIN rail, place the top edge of the 35mm industrial DIN rail, place a flat head included mounting bracket on the back of the screwdriver into the release clip found at the unit against the DIN rail at a 15°...
- Page 11 100 Series enclosures to standard 19" racks, and our Panel Mount Assembly (P/N: 1000-PM) may be used to mount the metal clip versions of the 100 Series enclosures to a panel or any other flat surface. NOTE: the 1000-PM will only work with the factory installed –MDR metal clip options and it is not acceptable for the 116TX units.
-
Page 12: Front Panel
FRONT PANEL LED Status For 102MC, 104TX, 105FX, 106FX2, 108TX and 105TX-SL From Top to Bottom: Speed LED LNK/ACT Link/Activity LED RJ45 Ports Auto sensing 10/100BaseT Connection Green LED lights when Power is connected (Revised 2015-09-22) - Page 13 NOTE: The top LED indicates Link/Activity (LNK/ACT), and the lower LED indicates Speed (SPD) status. LED’s: The table below describes the operating modes: Color Description Power is Applied. Power is OFF. Link established, no Activity on cable. BLINKING Link established, Activity on cable LNK/ACT No link activity on cable.
-
Page 14: Applying Power
No link activity on cable. APPLYING POWER • 102MC, 104TX, 105TX, 105FX, 106FX2, 108TX, and 116TX Power Connector (Top View) • 110FX2, 111FX3, 112FX4, and 114FX6 Power Connector (Top View) (must be powered by Class 2 source only) Unscrew & Remove the DC Voltage Input Plug from the top header. Install the DC Power Cables into the Plug (observing polarity on unit). - Page 15 The best noise immunity and emissions (i.e. CE) are obtained when the N-Tron switch chassis is connected to earth ground via a drain wire. Some N-Tron...
- Page 16 In some cases, N-Tron switches with metal brackets can be supplied with optional plastic brackets if isolation is required. Users may run a drain wire & lug from the screw provided on the back face of the enclosure. In the event the provided grounding screw has been lost, care should be taken to limit the penetration of the outer skin by less than 1/4".
-
Page 17: Rj45 Connector Crimp Specifications
In the event all Cat5e patch cable distances are small (i.e. All Ethernet devices are located the same local cabinet and/or referenced to the same earth ground), it is permissible to use fully shielded cables terminated to chassis ground at both ends in systems void of low level analog signals. RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration for your... -
Page 18: Troubleshooting
~ 2X. 3. Verify that Link LED’s are ON for connected ports. 4. Verify cabling used between stations. 5. Verify that cabling is Category 3 or greater for 10Mbit Operation. SUPPORT Contact N-Tron Corporation at: TEL: 251-342-2164 FAX: 251-342-6353 WEBSITE: www.redlion.net E-MAIL: customer.service@redlion.net... - Page 19 100BaseFX: SC or ST Duplex Port Recommended Minimum Wiring Clearance: Top: 1 " (2.54 cm) Front: 4 " (10.16 cm) Warranty: Effective January 1, 2008, all N-TRON products carry a 3 year warranty from the date of purchase. (Revised 2015-09-22)
- Page 20 Regulatory Approvals: Safety: Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations, or Nonhazardous Locations only. EMI: EN61000-6-4, EN55011 - Class A FCC Title 47, Part 15, Subpart B - Class A ICES-003 – Class A EMS: EN61000-6-2 EN61000-4-2 (ESD) EN61000-4-3 (RS)
This manual is also suitable for: